The client was motivated to reduce their energy use and to improve their thermal comfort in this beautiful home in west Aberdeen
They were also unsure about how long they might live in the home and hence wanted to know that their investment would have some improvement on their property value
The home was originally built in the 1920s, with two more recent extensions and a room-in-roof conversion. Many of the existing period features were to be retained.
Our Whole House Retrofit service was chosen to evaluate all the options and our Retrofit Coordinators guided them through the project from start to finish.
Local contractors were used for all the measures
Services Provided:
☑ Retrofit Assessment
☑ Air Permeability Testing
☑ Retrofit Design
☑ Building Warrant Approval
☑ On-site Retrofit Coordination
Retrofit Assessment
Our survey uncovered numerous area of improvement:
- Missing Insulation
- Incomplete Insulation
- Thermal Bypass
- Thermal Bridging
- Airtightness
- Leaking Floor boards
- Poor cable and pipe finishing
- Poor sealing windows
- Leaking ceiling lights
Thermal bridging at alcoves
Thermal bridging at alcoves
Lack of insulation in the room-in-roof space
Lack of insulation in the room-in-roof space
Thermal bridging of bay windows
Thermal bridging of bay windows
Failed glazing in an overheating conservatory
Failed glazing in an overheating conservatory
No floor insulation or pipe lagging
No floor insulation or pipe lagging
Leaking windows
Leaking windows
The Retrofit Plan
A multi-stage retrofit plan was adopted to implement gradual improvements with check points between each stage to chart progress
Stage 1
✅ Room-in-Roof Insulation
✅ MVHR Ventilation System
✅ Airtightness Measures
Total Predicted Saving: 42%
Stage 2
✅ Underfloor airtightness and insulation measures
✅ Airtightness measures
Total Predicted Saving: 52%
Stage 3
✅ Conservatory Upgrades
Total Predicted Saving: 55%
Stage 4 (Future measures)
Further Airtightness measures
Heat Pump Installation
Internal Wall Insulation (if required)
Measures Installed
✅ Room-in-Roof Insulation
✅ MVHR Ventilation System
✅ Underfloor airtightness and insulation
✅ Airtightness Measures
✅ Conservatory Upgrades
Mechanical Ventilation with Heat Recovery
Mechanical Ventilation with Heat Recovery
Airtightness membranes
Airtightness membranes
Room in Roof Insulation
Room in Roof Insulation
Repair works to the house render
Repair works to the house render
Sunroom upgrade to improve heat retention and to reduce overheating
Sunroom upgrade to improve heat retention and to reduce overheating
Underfloor insulation with airtightness measures
Underfloor insulation with airtightness measures
Airtightness to lath & plaster
Airtightness to lath & plaster
Disruption
The client stayed in their home while the work was carried out
Duration
Stage 1 took around 4 months to complete
The Results
Not only did the client achieve their ambitions of decarbonising their heating, they also achieved much better indoor air quality and comfortable evenly balanced temperatures throughout the house
Client feedback
​​​​​​​The house is much warmer than before and the air is always fresh, I’m really pleased with the results so far!

You may also like